Page 1
GEFRAN will not be liable for any damage to persons and/or property, or to the product itself, caused by failure to follow the instructions and observe the warnings given below.
REVISION DOCUMENTS DATE CODE UPDATE 07-2013 80991B Document issue 09-2017 80991C Addition of UL certification. CE certification update 80991C_MHW_GF_VEDO SL_09-2017_ENG...
SUMMARIES AND TABLES OF CONTENTS REVISION DOCUMENTS ...........2 ENTRY INTO SERVICE ............17 Set-up program ................17 SUMMARIES AND TABLES OF CONTENTS ....3 Main Menu ................17 Configuration .................17 PREFACE ................4 Network .................18 Warnings and safety ..............4 Display ...................18 Printing conventions used in the manual ........4 Touchscreen calibration ............18 Glossary ..................5 Information ................19...
Gefran S.p.A. also reserves the right to make changes to Before interacting with the Controller and built-in Operator the contents and form of this manual and to the characteri-...
Glossary Controller Area Network, also known as RS-232 Standard which defines a low-speed se- CAN-bus, is a standardised bus that rial transmission interface for the exchan- enables the devices to communicate ge of data between digital with each other. devices, such as modems. CANopen RS-485 CAN communication protocol.
GENERAL Overview of the solution and functionalities GF_VEDO SL is the complete process and automation con- Thanks to its flexibility and ease of use can be used in a va- trol solution, which allows sequence control, process mana- riety of sectors and for numerous process and automation gement, programming and display of data and connectivity process controls, such as: with a single modular system.
GF_VEDO series SL models 35CT – 70CT – V70CT The integrated Controller and Operator Panel allows the complete management of automation. GF_VEDO_SL - 35CT Available in 3 versions: 35CT 3,5” color touch; 70CT 7” color touch for horizontal installation; V70CT 7” color touch for vertical installation; and equipped with a powerful 400 MHz processor.
Technical data POWER Operating voltage 24 Vdc ±25% Absorbed current 300 mA max 350 mA max (at 24 Vdc) Dissipated power 7.5 W max 8.5 W max Protections Protection for polarity inversion Short circuit Connection 3-pole polarised extractable connector Screw terminals, max wire section 2,5 mm² BACK-UP BATTERY Type Rechargeable Li-Al 3 V 65 mA/h, type ML2032, non-replaceable...
Technical data ENVIRONMENTAL Operative temperature 0 ... +50 °C (according to IEC 68-2-14) CONDITIONS Storage temperature -20 ... +70 °C (according to IEC 68-2-14) Relative humidity max 95% RH non condensing (according to IEC 68-2-3) ASSEMBLY Embedded, in control panels DEGREE OF IP 65 on the front (according to IEC 68-2-3) PROTECTION...
Page 11
GF VEDO SL 35CT GF VEDO SL 70CT - V70CT Figure 3 - Free spaces for ventilation Attention: the temperature inside the compartment that houses the integrated Controller and Operator Panel must never exceed 50 °C. The free spaces highlighted in grey are those recommended with static ventilation.
ASSEMBL Y AND INSTALLATION Assembly of Integrated Controller and Operator Panel UL requirements Operator Panel is mounted has to have the following cha- racteristics: - Installation category (overvoltage category) II. • be sufficiently stiff and strong so that it does not bend - A device suitable for use in environments with pollution degree 2.
120° 45° Figure 5 - GF_VEDO SL admitted angulation Figure 6 - Position and angulation The angulation of the controller must be between 45° and The angulation to choose also depends on the position of the 120°, as shown in figure 5. controller compared to the operator, as shown in figure 6.
1 2 3 FERRITE CAN_L CAN_H Figure 12 - CAN bus line termination +VI24 GNDI +24 Vdc ±25% The line termination is not fitted in the controller. 350 mA max It is therefore necessary to fit two terminations (resistor 120 Ω, ¼ W, 5%) at the ends of the CAN Figure 11 - GF_VEDO SL power connection bus, as shown in figure 12.
The USB port is optional and is used to connect external devices compliant to the USB standard. The connector is Type A and the port supports version USB 2.0, with speed up to 480 Mbit/s. The port is able to issue a current of 500 mA at 5 Vdc to Name Description power USB devices.
Switch the controller again. After the initial start phase, positioned on F, the following happens: the application program screen appears. The Gefran logo appears on the screen. Main Menu The operating system is loaded (this takes about 1mi). The Main Menu of the set-up program appears.
Display To regulate the date, proceed as follows: Touch the year with a finger. The numeric keypad appe- ars. Type in the year and press Enter. The changed year appears underlined. Touch the month with a finger. The numeric keypad appears.
Information Modbus TCP The HOME button in the top left corner allows a return to This screen shows the Node number of the Integrated Con- the Main Menu. troller and Operator Panel for the Modbus TCP protocol and The CANopen, Modbus TCP and Modbus RTU buttons information on the status of the Modbus TCP protocol.
System Message / Fault 11. Upload the application onto the controller, selecting -> Download Code from the Communication menu. Click the Yes button in the warning message that opens. The transfer starts and is highlighted on a progress bar. 12. At the end of the transfer, a window opens and asks you to restart the system.
MAINTENANCE AND DIAGNOSTICS Maintenance Integrated Controller and Operator Disposal Panel The Integrated Controller and Operator Pa- To clean the screen use a slightly damp soft cloth. nel and the CAN-IO module must be dispo- Do not use chemical or abrasive products. sed of in compliance with the laws in force.
RS485 + RS232 Ports Absent Absent seriale RS485+RS232+ slot SD card CAN Port Absent CANopen (1) Mandatory port for use with remote IO GEFRAN spa reserves the right to make aesthetic and/or functional changes at any time and without notice. 80991C_MHW_GF_VEDO SL_09-2017_ENG...
Page 23
GF_VEDO SL 35CT color touch Code Model Description GF_VEDO SL 35CT Integrated unit for the complete management of the machine and process automation. 3.5” TFT color display, 262K colors, resolution 320x240 pixels QVGA, analog and resistive touch screen, GF_VEDO SL 35CT LX0 00 00 00 00 F055183 Built-in Ethernet port, integrated SoftPLC [standard IEC61131-3], ARM9,...
Page 24
GF_VEDO SL 35CT color touch with 6 programmable function keys Code Model Description GF_VEDO SL 35CT Integrated unit for the complete management of the machine and process automation. 3.5” TFT color display, 262K colors, resolution 320x240 pixels QVGA, analog and resistive touch screen, GF_VEDO SL 35CT LX0 00 00 00 K1 Built-in Ethernet port, integrated SoftPLC [standard IEC61131-3], ARM9,...
RS485 + RS232 Ports Absent Absent seriale RS485+RS232+ slot SD card CAN Port Absent CANopen (1) Mandatory port for use with remote IO GEFRAN spa reserves the right to make aesthetic and/or functional changes at any time and without notice. 80991C_MHW_GF_VEDO SL_09-2017_ENG...
Page 26
GF_VEDO SL 70CT color touch Code Model Description GF_VEDO SL 70CT Integrated unit for the complete management of the machine and process automation. 7” TFT colors display, 262K colors, resolution 800x480 pixels WVGA, GF_VEDO SL 70CT LX0 00 00 00 00 analog and resistive touch screen, Build-in Ethernet port, integrated F055186 SoftPLC [standard IEC61131-3], ARM9, 400MHz processor, Flash 128...
Page 27
GF_VEDO SL 70CT color touch with 10 programmable function keys Code Model Description GF_VEDO SL 70CT Integrated unit for the complete management of the machine and process automation. 7” TFT colors display, 262K colors, resolution 800x480 pixels WVGA, analog and resistive touch screen, GF_VEDO SL 70CT LX0 00 00 00 K1 Build-in Ethernet port, integrated SoftPLC [standard IEC61131-3], ARM9,...
RS485 + RS232 Ports Absent Absent seriale RS485+RS232+ slot SD card CAN Port Absent CANopen (1) Mandatory port for use with remote IO GEFRAN spa reserves the right to make aesthetic and/or functional changes at any time and without notice. 80991C_MHW_GF_VEDO SL_09-2017_ENG...
Page 29
GF_VEDO SL V70CT color touch - vertical installation Code Model Description GF_VEDO SL V70CT Integrated unit for the complete management of the machine and process automation. 7” TFT colors display, 262K colors, resolution 480x800 pixels WVGA, analog and resistive touch screen, GF_VEDO SL V70CT LX0 00 00 00 00 F0567936 Build-in Ethernet port, integrated SoftPLC [standard IEC61131-3], ARM9,...
Page 30
GF_VEDO SL V70CT color touch with 10 programmable function keys - vertical installation Code Model Description GF_VEDO SL V70CT Integrated unit for the complete management of the machine and process automation. 7” TFT colors display, 262K colors, resolution 480x800 pixels WVGA, analog and resistive touch screen, GF_VEDO SL V70CT LX0 00 00 00 K1 Build-in Ethernet port, integrated SoftPLC [standard IEC61131-3], ARM9, F056974...
Programming tool GF_PROJECT LX Development software that allows the writing of the application program for PLC with IEC1131 languages. Also allows the construction, in graphic mode, of the various pages of the user interface necessary to the application deve- loped. Via GF_PROJECT LX it is possible to connect to the device that will host the application to debug the program and upload the upgrades.
Need help?
Do you have a question about the GF VEDO SL Series and is the answer not in the manual?