1-4-6 Mark on Vertical Cone

„ Sample
Bottom-base
Diameter of
Cone: 30 mm
Marking Image
Original Point of
Local Coordinate
4mm
-8mm
„ Setting Flow
1. Set the cone (marking on cone with its heightwise set parallel to Z axis).
Set the size, angle, and center position of the cone (marking on cone with its heightwise set parallel to Z
axis).
2. Set the marking condition.
Set the character type and character position to be marked on the cone (marking on cone with its heightwise
set parallel to Z axis).
70
Top-base Diameter
of Cone: 10 mm
Height: 8 mm
Center of
3D Figure
Z
30mm
Original Point of World Coordinate
Marking Figure
[Setting of figure]
• Layer No.
• Work Shape
• Top-base Diameter
• Bottom-base Diameter
• Height
• Center X
• Center Y
• Center Z
[Character Condition]
• Marking content
• Marking Shape
• Center X
• Center Y
• Center Z
• Start Angle
• Character Interval Angle
• Character Height
• Character Width
Start Angle:
-160°
ME-LPMSZ-OP-7
:
0
:
Ver. Cone Convex
:
10 mm
:
30 mm
:
8 mm
:
-8 mm
:
30 mm
:
4 mm
:
ABCD1234
:
Arc inside (-)
:
0 mm
:
0 mm
:
12 mm
:
-160 degree
:
20 degree
:
4 mm
:
3 mm
Original Point of
Local Coordinate
(Center Position
(X, Y))
Radius: 12 mm
Character Interval
Angle: 20 degree
Marking Character