Panasonic LP-M Series Operation Manual page 160

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

„ CODE39, ITF, CODE128, NW-7, EAN/UPC
1
2
5
9
8
CODE128, EAN/UPC
Description
1
Bar Code Height :
Specifies the height of bar code. The bar code height does not include the height of the human readable character.
Setting Range
2
Narrow Element Width :
Specifies narrow element width of the bar code.
Set the larger value than 'Line width' in laser setting screen.
Setting Range
3
Quiet Zone / Narrow Element Ratio :
Ratio of the quiet zone to narrow element width. Specifying the number other than "0" here makes it possible to view the
image of the quiet zone if the inversion marking is not performed.
Setting Range
4
Wide Element / Narrow Element Ratio (only for CODE39 / ITF / NW-7) :
Ratio of wide element to narrow element.
Setting Range
5
Inversion :
Enable this function to mark the bar code inverted. Without inversion setting, only the bars are marked. With the
inversion setting, the quiet zone and space in the symbol section are marked.
6
Check Character :
Mark the check box to include check character in the bar code.
Setting this check character function inputs the following check character automatically.
• CODE 39: modulus 43
• ITF: modulus 10/weight 3-1
• NW-7: modulus 16
Reference
• For CODE 128, inputting "FNC1" and "01" at the head of the bar code data followed by 13-figure numeric automatically
input one check digit (modulus10/weight 3-1).
• For 1D of Composite whose lower bar code consists of UCC/EAN128, inputting "01" at the head of the bar code data
followed by 13-figure numeric automatically input one check digit (modulus10/weight 3-1).
160
3
1.000 to 120.000 mm (LP-M500 / LP-Z130)*
1.000 to 90.000 mm (LP-S500)*
0.050 to 1.000 mm
0.0 to 20.0
1.8 to 3.4
6
7
ME-LPMSZ-OP-7
4
NW-7, CODE39, ITF

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents