Panasonic LP-M Series Operation Manual page 275

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

ERROR
CODE
E902
Cannot create 2D code.
E903
No specified 2D code pattern.
E910
Existed invalid character for converting into bar code.
E911
Cannot create bar code.
Too small dimension of narrow element/basic module
E912
width for bar code.
E913
No quiet zone in bar code.
E914
Too small separate pattern or composite row height.
E915
Cannot create bar code.
E916
Cannot mark bar code with sphere or vertical cone.
*1
*1 : Error that may occur for LP-M / LP-Z series only.
*2 : Error that may occur for LP-S series only.
*3 : Error that may occur for LP-M / LP-S series only.
*4 : Error that may occur for LP-Mxxx-S type only.
*5 : Error that may occur for LP-M series only.
Reference
• When other error not listed in this section was occurred, restart the laser marker.
• If the symptom persists after restart, contact our sales office.
Error description
ME-LPMSZ-OP-7
Measures
Use the condition where 2D code can be created.
Specify 2D pattern code which has been already
registered.
Set the character that can be bar coded.
Use the condition where a barcode can be
created.
Specify the setting value for the width of the
narrow element/basic module larger than that of
the line width of the laser.
Set the proper value for "Quiet/Narrow Ratio".
With the inversion setting, set always quiet zone.
• Correct the "Separator Height/(W)" or "One Bar
Code H." settings so that the height is larger
than the "Line Width" in the laser settings.
• If you want to remove the separator, set 0 to
the "Separator Height/(W)".
Digit number of characters for EAN/ UPC code or
GS1 DataBar code is incorrect.
Enter the prescribed number of characters
according to the code type.
• With 3D setting of sphere or vertical cone, do
not use the barcode setting.
• Set the work shape other than sphere and
vertical cone.