Laser Power Correction
After the power check if the power decays lower than the delivery status, correct the laser power setting value.
Select the correction mode from "Auto" or "Manual".
• Auto: Sets the power correction ratio with the auto-calculated value so as to set the power to the power output at
shipping.
• Manual: Corrects the power setting with the given value [%].
WARNING
1.
Press [POWER CHECK].
2.
The Confirm screen is displayed.
Press [START].
The current laser marker power is measured.
3.
For the auto correction, Press "AUTO".
For the manual correction, press "MANUAL" and input
power correction value, then press [SET].
Setting range: 50 to 200[%]
4.
Press [START].
The correction ratio after power correction and correction date are
updated.
• Laser is radiated with the internal shutter closed. Be sure to use the protective
goggle and enclosure in case of laser leakage. Also, do not place any objects
around the radiating area.
LP-SxxxW type
ME-LPMSZ-OP-7
LP-Z series
247