Setting for Vertical Cone
Description
Height :
Sets the height of the vertical cone.
Setting Range
1.000 to 120.000 mm (LP-M500 / LP-Z130)*
Diameter 1 :
Sets the diameter (+Z side) of the vertical cone.
When mark on convex face: Set smaller diameter as "Diameter 1" and larger diameter as "Diameter 2".
When mark on concave face: Set larger diameter as "Diameter 1" and smaller diameter as "Diameter 2".
Setting Range
1.000 to 120.000 mm (LP-M500 / LP-Z130)*
Diameter 2 :
Sets the diameter (-Z side) of the vertical cone.
When mark on convex face: Set smaller diameter as "Diameter 1" and larger diameter as "Diameter 2".
When mark on concave face: Set larger diameter as "Diameter 1" and smaller diameter as "Diameter 2".
Setting Range
1.000 to 120.000 mm (LP-M500 / LP-Z130)*
* For the setting range of the other model, refer to "Input Setting Value by Series" (P.296).
Rotation Angle Z
Center Position
(X, Y, Z)
Height
Diameter 2
Setting items for concave face of vertical cone
142
Rotation
Angle Y
Diameter 1
Rotation
Angle X
ME-LPMSZ-OP-7
Rotation
Angle Z
Center Position
(X, Y, Z)
Diameter 2
Setting items for convex face of vertical cone
Diameter 1
Rotation
Angle Y
Length
Rotation
Angle X