1-4-3 Mark on Cylinder

„ Sample
Diameter: 20 mm
Marking Image
Center of 3D Figure
Original Point of
World Coordinate
20mm
„ Setting Flow
1. Set the cylinder.
Set the size, angle, and center position of the cylinder.
2. Set the marking condition.
Set the character type and character position to be marked on the cylinder.
Length of Cylinder: 15 mm
Original Point of
Local Coordinate
Z
18mm
Marking Figure
ME-LPMSZ-OP-7
[Setting of figure]
• Layer No.
• Work Type
• Diameter
• Diameter
• Center Position X
• Center Position Y
• Center Position Z
[Character condition]
• Marking content
• Starting Coordinate X
• Starting Coordinate Y
• Character Height
• Character Width
• Character Interval
-2mm
10mm
X Position,
Y Position
(Character Condition)
: 0
: Cylinder (convex face)
: 20 mm
: 15 mm
: 20 mm
: 18 mm
: 10 mm
: ABCD
: -8 mm
: -2 mm
:
4 mm
:
3 mm
:
4 mm
Y
ABCD
X
Original Point of
-8mm
Local Coordinate
Marking Character