E va l u a t i n g L i n k Q u a l i t y
28.4.2. Measuring BER Using WipManage
You can measure BER using WipManage.
To measure BER using WipManage:
1.
Open the BSR Zoom window pertaining to the BSR whose BER you want to
measure.
2.
From the Performance menu, point to Air, point to Cell, and then choose BER
per SPR.
The BER per SPR window is displayed below.
28-12
Figure 28-5: BER per SPR graph
Airspan Networks Inc.
C o m m i s s i o n i n g M a n u a l
01040311-07