Ricoh FT8680 Service Manual page 379

Table of Contents

Advertisement

31 July 1995
SC505 - 1st Tray Drive Abnormal
Definition:
The main PCB cannot detect any pulses from the first tray paper volume
sensor within 3 seconds after the tray up or down operation has been started.
Points to check:
Mechanical interference with the tray drive
Paper volume sensor
Tray drive motor
Interface PCB
FU2 on the power supply unit (dc 24 V)
Main PCB
SC507 - 1st Tray Lower Limit Sensor Failure
Definition:
The main PCB cannot detect the lower limit sensor signal within 4.5 seconds
after the tray down operation has been started.
Points to check:
Lower limit sensor
Tray drive motor
Tray drive wires
Interface PCB
SC508 - 2nd Tray Drive Abnormal
Definition:
The main PCB cannot detect any pulses from the 2nd tray paper volume
sensor within 3 seconds after the tray up or down operation has been started.
Points to check:
Mechanical interference with the tray drive
Paper volume sensor
Tray drive motor
Interface PCB
FU2 on the power supply unit (dc 24 V)
Main PCB
SYSTEM ERROR AND SERVICE CALL CONDITIONS
6-17