SYSTEM ERROR AND SERVICE CALL CONDITIONS
SC307 - Vd Correction Error
Definition:
During process control data initialization, the target Vd value cannot be
achieved within the charge power pack output range.
NOTE: After resetting the system error condition, Vd correction will be
tried again. Even if the second execution fails, no service call
condition is displayed and the copier uses previous reference
data until its next initialization.
Points to check:
Drum
Vd pattern
Charge corona
Charge corona power pack
Drum potential sensor
FU3 on the power supply unit (dc 24 V: VP)
SC352 - Vsp Abnormal
Definition:
The main PCB detects a high Vsp value (1.4 V) five times in a row.
NOTE: Toner supply shifts to 7% fixed toner supply mode. If the Vsp
returns to normal level, standard detect supply resumes. No
service call condition is displayed.
Points to check:
ID sensor
Toner supply mechanism
Toner near end sensor
Drum
Developer
Development bias
Charge corona
6-10