INSTALLATION PROCEDURE (COPIER)
[B]
19. Connect the operation unit [A] to the operation unit stand [B] (4 screws
and 2 connectors).
20. Install the operation unit (1 M5 x 8 screw [C] and 1 connector [D]) and the
operation unit stopper [E] (2 M5 x 8 screws). The oval hole [F] of the
operation unit stopper should be at the lower position.
NOTE:
2 height positions of the operation unit can be selected by the
positions of securing screw [C].
The operation unit can be moved left to right by removing one
M5 x 8 screw [C] when the operation unit is mounted at the
lower position.
21. Secure the grounding wire [G] of the operation unit (1 screw) and reinstall
the right rear cover.
22. Install the drum guide bracket [H] (1 screw) and set the drum guide [I] to
the lower inner cover.
[A]
A171I513.img
A171I506.img
[E]
[F]
[C]
[D]
[G]
[H]
[I]
3-10
31 July 1995
A171D528.img