Parameter Description
3.15.6 15-6* Option Ident.
This read-only parameter group contains information about
the hardware and software configuration of the options
installed in slots A, B, C0 and C1.
3
3
15-60 Option Mounted
Range:
0
[0 - 0 ]
*
15-61 Option SW Version
Range:
0
[0 - 0 ]
*
15-62 Option Ordering No
Range:
0
[0 - 0 ] Shows the ordering number for the installed
*
15-63 Option Serial No
Range:
0
[0 - 0 ]
*
15-70 Option in Slot A
Range:
0
[0 - 0 ] View the string for the option installed in slot A,
*
15-71 Slot A Option SW Version
Range:
0
[0 - 0 ] View the software version for the option installed
*
15-72 Option in Slot B
Range:
0
[0 - 0 ] View the string for the option installed in slot B,
*
15-73 Slot B Option SW Version
Range:
0
[0 - 0 ] View the software version for the option installed
*
15-74 Option in Slot C0
Range:
0
[0 - 0 ] View the string for the option installed in slot C,
*
118
Function:
View the installed option type.
Function:
View the installed option software version.
Function:
options.
Function:
View the installed option serial number.
Function:
and a translation of the string. E.g. for string 'AX'
the translation is 'No option'.
Function:
in slot A.
Function:
and a translation of the string. E.g. for string 'BX'
the translation is 'No option'.
Function:
in slot B.
Function:
and a translation of the string. E.g. for string
'CXXXX' the translation is 'No option'.
MG.11.CC.02 - VLT
®
VLT
HVAC Drive Programming Guide
15-75 Slot C0 Option SW Version
Range:
0
[0 - 0 ] View the software version for the option installed
*
15-76 Option in Slot C1
Range:
0
[0 - 0 ] Shows the typecode string for the options (CXXXX
*
15-77 Slot C1 Option SW Version
Range:
0
[0 - 0 ] Software version for the installed option in option
*
15-92 Defined Parameters
Array [1000]
Range:
0
[0 - 9999 ] View a list of all defined parameters in the
*
15-93 Modified Parameters
Array [1000]
Range:
0
[0 - 9999 ] View a list of the parameters that have been
*
15-98 Drive Identification
Range:
0
*
15-99 Parameter Metadata
Array [23]
Range:
0
[0 - 9999 ] This parameter contains data used by the
*
®
is a registered Danfoss trademark
Function:
in slot C.
Function:
if no option) and the translation i.e. >No option<.
Function:
slot C.
Function:
frequency converter. The list ends with 0.
Function:
changed from their default setting. The list
ends with 0. Changes may not be visible until
up to 30 sec. after implementation.
Function:
[0 - 0 ]
Function:
MCT10 software tool.