Analysis Using Listing - Agilent Technologies 16712A Help Manual

128k sample logic analyzer
Table of Contents

Advertisement

Chapter 1: Agilent Technologies 16712A 128K Sample Logic Analyzer
Interpreting the Data
help volume)
Using the Listing Display Tool (see the Listing Display Tool help volume)
Using the Chart Display Tool (see the Chart Display Tool help volume)
Using the Distribution Display Tool (see the Distribution Display Tool
help volume)
Using the Compare Analysis Tool (see the Compare Tool help volume)
Using the Pattern Filter Analysis Tool (see the Pattern Filter Tool help
volume)

Analysis Using Listing

Listing is more useful than Waveform when your target system is
running code because it shows the labels as states rather than
transitions. Listing is especially useful when you have defined
meaningful symbol names for your states. If you have an inverse
assembler, you might prefer Source Viewer which functions like
Listing.
Example: Examining a Subroutine
Listing is the preferred display tool for state measurements. for
example, if you were trying to see if a subroutine were exiting
abnormally, you might want to measure the number of states between
entering and exiting the subroutine. After acquiring data with the logic
analyzer, you could examine the data set in the Listing display like this:
1. Find the start of the subroutine.
Assume the subroutine starts at the address 0x58FC.
a. Select the Search tab.
b. Select the down arrow after the Label field, and select ADDR.
c. Select the Value field, and enter the starting address, 0x58FC.
d. Select the down arrow after the When field and select Present.
e. Select the Next or Prev button to move the display to the address.
28
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com