Agilent Technologies 16712A Help Manual page 103

128k sample logic analyzer
Table of Contents

Advertisement

Chapter 1: Agilent Technologies 16712A 128K Sample Logic Analyzer
The Trigger Tab
write, places it in the approximate center of the next available record,
and surrounds it with the states that preceded it and the states that
followed it.
After the measurement is complete, you view a list of writes to the
variable and see the routines that executed those writes.
Problems you may see
• If your store event occurs more often than is allowed by your choice of
context record size, your context records will be smaller than the size you
specified.
• If you select a context qualifier that excludes most states, it may take a
long time to complete a measurement.
See Also
"Using Bit Pattern Terms" on page 93
"Working with the User-level Function" on page 89 for how to set store
qualifiers.
Example: To Find Where Variables are Accessed From (see the
Measurement Examples help volume)
Example: To Trace Callers of a Function (see the Measurement Examples
help volume)
102
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Advertisement

Table of Contents
loading

Table of Contents