1.3.3 Cycle call and parameter list

The standard cycles use user-defined variables. You
can transfer the defining parameters for the cycles
via the parameter list when the cycle is called.
Cycle calls must always be programmed in a
separate block.
Basic instructions regarding assignment of
standard cycle parameters
The Programming Guide describes the parameter
list of every cycle together with the
• sequence and
• type.
The sequence of the defining parameters must be
observed.
Each defining parameter of a cycle is of a specific
data type. The parameter type in use must be
specified when the cycle is called. In the parameter
list, you can transfer
• variables or
• constants.
If variables are transferred to the parameter list, they
must first be defined as such and assigned values in
the calling program. Cycles can be called
• with an incomplete parameter list or
• by leaving out parameters.
If you want to exclude the last transfer parameters
that have to be written in a call, you can prematurely
terminate the parameter list with ")". If you wish to
leave out parameters in between, a comma, "...,
,..." is used as placeholder.
© Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Programming Guide Cycles (PGZ) – 11.02 Edition