Diagnosing And Resetting Faults; Diagnosing And Resetting Faults; Fault Occurs Simultaneously With Power Loss; If The Drive Still Has Power After A Fault Occurs - YASKAWA FSDrive-MV1000 Series Instructions For Use Manual

Super energy-saving medium-voltage ac drive
Hide thumbs Also See for FSDrive-MV1000 Series:
Table of Contents

Advertisement

5.10 Diagnosing and Resetting Faults

When a fault occurs and the drive stops, follow the instructions below to remove whatever conditions triggered the fault,
then restart the drive.
u Fault Occurs Simultaneously with Power Loss
WARNING! Sudden Movement Hazard. Ensure there are no short circuits between the main circuit terminals (U, V, W) or between
the ground and main circuit terminals before restarting the drive. Failure to comply may result in serious injury or death
and will cause damage to equipment.
1.
Turn on the drive input power.
2.
Use monitor parameters U2-
occurred.
3.
Remove the cause of the fault and reset.
Note: 1. To determine out what faults were triggered, check the fault history in U2-02 (Previous Fault). Information on drive status when the
fault occurred, such as the frequency, current, and voltage, can be found in U2-03 through U2-31.
Refer to
Viewing Fault Trace Data After Fault on page 181
2. When the fault continues to be displayed after cycling power, remove the cause of the fault and reset.
u If the Drive Still has Power After a Fault Occurs
1.
Turn the main circuit power supply off.
2.
Look at the digital operator for information on the fault that occurred.
3.
Refer to
Fault Displays, Causes, and Possible Solutions on page
4.
Remove the cause of the fault and reset.
Refer to
Fault Reset Methods on page
u Viewing Fault Trace Data After Fault
The checking method shown here uses an example in which the drive detects oL2 (Drive Overheat).
1 Turn on the drive input power. The first screen displays.
2 Press
until the monitor screen is displayed.
3 Press
to display the parameter setting screen.
4 Press
and
to scroll to monitor U2-01 (Previous Fault).
5 Press
to view previous fault (oL2 in this example).
YASKAWA ELECTRIC TOEP C710687 02B FSDrive-MV1000 Instructions
to display data on the operating status of the drive just before the fault
for information on how to view fault data.
182.
Step

5.10 Diagnosing and Resetting Faults

148.
Display/Result
5
181

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cimr-mv2 series

Table of Contents