Digital Operator Display
LIN
nn LINK FAULT
Cause
Fiber optic cable fault
The cell control board (CCB) or control board
has faulted
Digital Operator Display
oFA00
Cause
The option card installed into port CN5-A is
incompatible with the drive.
A PG option card is connected to option port
CN5-A.
Digital Operator Display
oFA01
Cause
The option card connection to port CN5-A is
faulty.
Digital Operator Display
oFA02
Cause
An option card of the same type is already
installed in option port CN5-B or CN5-C.
Digital Operator Display
oFA03 to oFA06
oFA10, oFA11
oFA12 to oFA17
oFA30 to oFA43
Cause
Option card or hardware is damaged.
Digital Operator Display
oFb00
Cause
The option card installed in port CN5-B is
incompatible with the drive.
A communication option card has been
installed in option port CN5-B.
Digital Operator Display
oFb01
Cause
The option card installed in port CN5-B has been
changed while operating.
The option card connection to port CN5-B is
faulty.
YASKAWA ELECTRIC TOEP C710687 02B FSDrive-MV1000 Instructions
CCB-MB Communication Error (Link Fault)
No response has not been returned within 1 ms or longer in the communication cycle.
Replace the fiber optic cable.
• Replace the CCB.
• Replace the control board. Contact Yaskawa or a Yaskawa representative for instructions on
replacing the control board.
Option Card Connection Error at Option Port CN5-A
Check if the drive supports the option card to be installed. Contact Yaskawa for assistance.
PG option cards are supported by option ports CN5-B and CN5-C only. Connect the PG option
card to the correct option port.
Option Card Fault at Option Port CN5-A
• Turn off the power and reconnect the option card.
• Check if the option card is properly plugged into the option port.
• If the option is not a communication option card, try to use the card in a different option port. If
the option card works properly in a different option port, CN5-A is damaged, and the drive
requires replacement. If the error persists (oFb01 or oFC01 occur), replace the option card.
Option Card Fault at Option Port CN5-A
Connect the option card properly. Except for PG options, only one of each option card type can
only be installed simultaneously.
Option Card Error Occurred at Option Port CN5-A
Option Card Fault at Option Port CN5-A
Option Card Error Occurred at Option Port CN5-A
• Cycle control power to the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a
Yaskawa representative for instructions on replacing the control board.
Option Card Connection Error at Option Port CN5-B
Make sure the drive supports the option card to be installed. Contact Yaskawa for assistance.
Communication option cards are only supported by option port CN5-A. It is not possible to
install more than one communication option.
Option Card Fault at Option Port CN5-B
Turn the control power off and reconnect the option card. Check if the option card is properly
plugged into the option port.
Try to use the card in a different option port (in case of a PG option, use port CN5-C). If the
option card works properly in a different option port, CN5-B is damaged, and the drive requires
replacement. If the error persists (oFA01 or oFC01 occur), replace the option card.
Fault Name
Possible Solutions
Fault Name
Possible Solutions
Fault Name
Possible Solutions
Fault Name
Possible Solutions
Fault Name
Possible Solutions
Fault Name
Possible Solutions
Fault Name
Possible Solutions
5.4 Fault Detection
5
155

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cimr-mv2 series

Table of Contents