Every 5 Calendar Years; Fire Extinguisher Reservoir; Emergency Flotation System - BELL HELICOPTER 430 Maintenance Manual

Volume 2: handling and servicing
Table of Contents

Advertisement

5-38.

EVERY 5 CALENDAR YEARS

DATA REFERENCE
Chapter 4
Chapter 26
Chapter 26
Chapter 99
SCHEDULED INSPECTIONS
INSPECTION TASK DESCRIPTION
DATE: __________________W.O. _____________________
FACILITY: _________________ _ ________________________
HELICOPTER S/N: __________ _ ________________________
REGISTRY NO.: ____________ _ ________________________
TOTAL TIME:_______________________________________
SIGNATURE:_______________ _ ________________________

FIRE EXTINGUISHER RESERVOIR

Refer to the Airworthiness Limitations for the time
between replacement schedule for the squib.
1.
Remove the right fire extinguisher reservoir. Do a
hydrostatic test in accordance with specification DOT-4 DA,
DOT-4 DS or DOT-SP-7945 as marked on container. (F4)
2.
Remove the left fire extinguisher reservoir. Do a hydrostatic
test in accordance with specification DOT-4 DA, DOT-4 DS or
DOT-SP-7945 as marked on container. (F3)

EMERGENCY FLOTATION SYSTEM

This inspection applies to any reservoir/cylinder
which has been manufactured or last retested after
July 1, 2006.
1.
Remove emergency flotation system nitrogen reservoir.
Perform a hydrostatic test in accordance with DOT-SP-8162
cylinder inspection.
NOTE
NOTE
26 JAN 2007 Rev. 15
BHT-430-MM-2
INITIAL
MECH OTHER
5-00-00
Page 101/102

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents