5-32.

EVERY 600 HOURS OF COMPONENT OPERATION

DATA REFERENCE
BHT-430-CR&O-V.2
Chapter 96
Chapter 96
Chapter 4
SCHEDULED INSPECTIONS
INSPECTION TASK DESCRIPTION
DATE: __________________W.O. _____________________
FACILITY: _________________ _ ________________________
HELICOPTER S/N: __________ _ ________________________
REGISTRY NO.: ____________ _ ________________________
TOTAL TIME:_______________________________________
SIGNATURE:_______________ _ ________________________

ENGINE STARTER-GENERATOR

The
component
inspection intervals can be followed as an alternate
means of compliance.
1.
Examine the right engine starter-generator brushes for
wear down to the diagonal groove wear indicator. (E2)
2.
Examine the left engine starter-generator brushes for wear
down to the diagonal groove wear indicator. (E1)

PYLON FLUID MOUNTS

Step 1
and
step 2
limitations.
This
inspection
430-310-200-103 and 430-310-200-105.
This inspection does not apply to part number
430-310-200-107.
1.
Examine the left pylon fluid mount as follows: (F5)
a. Remove the left pylon fluid mount.
NOTE
manufacturer's
recommended
NOTE
are airworthiness inspection
applies
to
part
numbers
26 JAN 2007 Rev. 15
BHT-430-MM-2
INITIAL
MECH OTHER
5-00-00
Page 87