Setting The Frequency Span - Span Key - Rohde & Schwarz R&S FSP Series Operating Manual

Spectrum analyzer
Table of Contents

Advertisement

R&S FSP
TRACK BW
The TRACK BW softkey defines the search bandwidth for signal tracking. The fre-
quency range is symmetrical with respect to the center frequency.
Remote command:
TRACK
The TRACK THRESHOLD softkey defines the threshold value for signal detection.
THRESHOLD
The value is always entered as an absolute level value.
Remote command:
SELECT TRACE
The SELECT TRACE softkey selects the trace on which signal tracking is to be per-
formed.
Remote command:
4.5.2
Setting the Frequency Span – SPAN Key
The SPAN key opens a menu which offers various options for setting the span.
The entry of the span (SPAN MANUAL softkey) is automatically active for span > 0
Hz.
For span = 0 Hz the entry for sweep time (SWEEPTIME MANUAL) is automatically
active.
With two windows (SPLIT SCREEN) displayed at the same time, the input data
always refer to the window selected with the SCREEN A/B hotkey.
SPAN
SPAN MANUAL
SWEEPTIME MANUAL
FULL SPAN
ZERO SPAN
LAST SPAN
FREQ AXIS (LIN LOG)
SPAN
The SPAN MANUAL softkey activates the window for manually entering the fre-
MANUAL
quency span. The center frequency is kept constant.
Allowed range of span values:
f
span
minspan
f
max
Remote command:
SWEEPTIME
The SWEEPTIME MANUAL softkey activates the window for entering the sweep
MANUAL
time manually with Span = 0 Hz. The softkey is not available for Span > 0 Hz.
Remote command:
Operating Manual 1164.4556.12 - 06
for the time domain (span = 0): 0 Hz
and for the frequency domain (span >0): minspan ≤ f
frequency span
smallest selectable span (10 Hz)
max. frequency
CALC:MARK:FUNC:STR:BAND 10KHZ
CALC:MARK:FUNC:STR:THR -70DBM
CALC:MARK:FUNC:STR:TRAC 1
FREQ:SPAN 2GHz
SWE:TIME 10s
Instrument Functions
Analyzer Mode
≤ f
span
max
4.13

Hide quick links:

Advertisement

Table of Contents
loading