Measuring The Spectra Of Complex Signals; Measurement Example - Measuring The R&S Fsp's Intrinsic Intermodulation Distance - Rohde & Schwarz R&S FSP Series Operating Manual

Spectrum analyzer
Table of Contents

Advertisement

R&S FSP
With an intermodulation distance of 60 dB and an input level, Pw, of –20 dBm, the
following 3
TOI = 60 dBm / 2 + (-20 dBm) = 10 dBm.
2.2.2
Measurement Example – Measuring the R&S FSP's intrinsic
intermodulation distance
To measure the intrinsic intermodulation distance, use the following test setup.
Test setup:
Signal
Generator 1
Signal
Generator 2
Settings on the signal generator (e.g. R&S SMIQ):
Signal generator 1
Signal generator 2
Measurement using the R&S FSP:
1. Set the R&S FSP to its default settings.
2. Set center frequency to 1 GHz and the frequency span to 1 MHz.
3. Set the reference level to –10 dBm and RF attenuation to 0 dB.
4. Set the resolution bandwidth to 10 kHz.
2.4
rd
order intercept is obtained:
Coupler
Level
-10 dBm
-10 dBm
Press the PRESET key.
The R&S FSP is in its default state.
Press the FREQ key and enter 1 GHz.
Press the SPAN key and enter 1 MHz.
Press the AMPT key and enter -10 dBm.
Press the RF ATTEN MANUAL softkey and enter 0 dB.
By reducing the RF attenuation to 0 dB, the level to the R&S FSP input mixer
is increased. Therefore, 3
Press the BW key.

Measuring the Spectra of Complex Signals

R&S FSP
Frequency
999.9 MHz
1000.1 MHz
rd
order intermodulation products are displayed.