• If pressure were slow to release at the end of the lid locking safety inspection, this
would indicate that either the solenoid valve needs to be cleaned or there is an
obstruction in the pressure solenoid plumbing.
8 8 . . 1 1 0 0 . . 1 1 C C l l e e a a n n t t h h e e D D e e a a d d W W e e i i g g h h t t P P l l u u m m b b i i n n g g
Remove rear cover of fryer.
1 1 ) )
Disconnect deadweight tube from dead weight hose (Figure 1).
2 2 ) )
Disconnect the dead weight tube from the dead weight assembly by loosening
3 3 ) )
the compression nut at the rear of the dead weight assembly.
Clean the dead weight tube.
4 4 ) )
Clean the dead weight valve using a small pipe snake.
5 5 ) )
Clean from the outlet in the fry pot to the deadweight valve (Figure 2).
6 6 ) )
Reassemble in reverse order.
7 7 ) )
8 8 . . 1 1 0 0 . . 2 2 C C l l e e a a n n t t h h e e S S o o l l e e n n o o i i d d P P l l u u m m b b i i n n g g
Inspect and clean the plumbing from the outlet in the fry pot to the pressure
1 1 ) )
solenoid.
Clean from the solenoid to the condensation box, see instructions for removal
2 2 ) )
and cleaning of the condensation box.