Henny Penny 500 Service Manual page 174

4-head electric pressure fryers
Hide thumbs Also See for 500:
Table of Contents

Advertisement

1 1 . . The air pump is always off during the first (10) seconds of the cook cycle, because the
user might still be trying to close the lid.
2 2 . . The air pump is always off if the pressure solenoid valve is off (open). The solenoid
valve cycles on and off according to the programmed cook cycle.