The voltage should read the same at each terminal. It should correspond to the
voltage rating stated on the data plate, see
Points , page
33.
NOTICE:
On fryers using three-phase power, check voltage as follows:
3 3 ) )
H H e e a a t t C C o o n n t t a a c c t t o o r r : :
• from terminal 34 to 35, see
• from terminal 35 to 36, see
• from terminal 24 to 36, see
The voltage should read the same at each terminal. It should correspond to the
voltage rating stated on the data plate, see
Points , page
33.
P P r r i i m m a a r r y y C C o o n n t t a a c c t t o o r r : :
• from terminal 27 to 28, see
33.
• from terminal 28 to 29, see
33.
• from terminal 27 to 29, see
33.
The voltage should read the same at each terminal. It should correspond to the
voltage rating stated on the data plate, see
Points , page
33.
2 2 . . 1 1 3 3 . . 4 4 R R e e p p l l a a c c e e m m e e n n t t S S q q u u a a r r e e D D
T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l s s h h o o c c k k o o r r p p r r o o p p e e r r t t y y d d a a m m a a g g e e , , m m o o v v e e t t h h e e
p p o o w w e e r r s s w w i i t t c c h h t t o o o o f f f f a a n n d d d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r
u u n n p p l l u u g g c c o o r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .
If either contactor is defective, it must be replaced as follows:
Remove only those wires directly connected to the contactor being replaced.
1 1 ) )
Label the wires.
Remove the two mounting screws on the base plate and remove contactor.
2 2 ) )
Install the new contactor and tighten the two mounting screws.
3 3 ) )
Connect the labeled wires to their respective positions.
4 4 ) )
Install the control panel per
5 5 ) )
Reconnect power to the fryer and test the fryer for proper operation.
6 6 ) )
Figure 2-9 Primary Contactor Test
If voltage is not present, check output of primary
contactor at terminals 27, 28, and 29.
Figure 2-10 Heat Contactor Test Points , page
Figure 2-10 Heat Contactor Test Points , page
Figure 2-10 Heat Contactor Test Points , page
Figure 2-9 Primary Contactor Test
Figure 2-9 Primary Contactor Test Points , page
Figure 2-9 Primary Contactor Test Points , page
Figure 2-9 Primary Contactor Test Points , page
Figure 2-9 Primary Contactor Test
2.4.1 Raise the Control , page
34.
34.
34.
14.
35