8 8 . . 2 2 3 3 . . 6 6 C C o o i i l l C C h h e e c c k k P P r r o o c c e e d d u u r r e e
1. Remove power from the fryer by unplugging from the power source.
2. Remove wires from terminals 73 and 72 and check ohms across the solenoid wires.
V V o o l l t t s s / / P P h h a a s s e e :
- 120 volt 60 Hz
- 208-240 volt 60 Hz
- 208-240 volt 50 Hz
8 8 . . 2 2 3 3 . . 7 7 L L o o c c k k i i n n g g P P i i n n T T e e s s t t P P r r o o c c e e d d u u r r e e
Ensure the lid locking pin engages the locking collar of the spindle when the pressure
in the fry pot reaches 2 psi and greater and also to ensure the lid locking pin remains
engaged as pressure releases at 2 psi. Refer to the
Figure 1
Figure 2
T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l s s h h o o c c k k o o r r p p r r o o p p e e r r t t y y d d a a m m - -
a a g g e e , , m m o o v v e e t t h h e e p p o o w w e e r r s s w w i i t t c c h h t t o o O O F F F F a a n n d d
d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r u u n n p p l l u u g g
c c o o r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .
R R e e s s u u l l t t s s : :
- 50 ohms
- 150 ohms
- 245 ohms
Annual Inspection on
1. Remove the reducer from the test
fixture (Figure 1).
2. Install the supplied elbow from the test
fixture into the t-fitting with pipe
thread sealant (Figure 2).