Table 6-1 Programming - Henny Penny 500 Service Manual

4-head electric pressure fryers
Hide thumbs Also See for 500:
Table of Contents

Advertisement

C C h h a a p p t t e e r r 6 6 P P r r o o g g r r a a m m m m i i n n g g
Programming information is provided in this section. Operator menus are described in
the Operator's manual and are not included in this manual. All menus that pertain to
maintenance are described in this section. To enter the menus, perform the following
steps:
Press and hold the PROGRAM button for five seconds.
1 1 ) )
Release the PROGRAM button as soon as "LEVEL 2" shows in the display.
2 2 ) )
Press the PROGRAM button until "TECH" is displayed (you are in tech mode
3 3 ) )
now).
Enter the code 11221122.
4 4 ) )
The only menu used for maintenance for the Computron 8000 control is Tech Mode.
Menu Step
T-1 Software
View software ID's
ID's
Press and hold [1]: HP P/N = 32609J (HP part number for software.)
Press and hold [2]: ID = HP C8000 (The specific customer or model num-
ber, etc.)
Press and hold [3]: SRL = 1.50 (Software Release Level (version) for this
software.)
T-2 Fryer Type
Auto-detected by the controller, based on I/O board and wiring harness
connections. (This is not a setting you can adjust.)
Auto-detection can complete only if the fryer is turned ON and the high-
limit and drain switch interlocks are closed. If the display indicates
"NEED VHDS", then one of the interlocks is not satisfied and the auto-
detect routine is unable to proceed.
T-3 Push-Button
Push-button test mode.
Test
Press and release buttons (starting with any button other than INFO or
PROG) to activate test mode. Main display shows an indicator letter for
each button that is pressed:
Number buttons 1-0, Info, Down, Up, Prog, Left-side (Idle), Right-side
(Timer)
T-4 All-On Dis-
Press and hold any number button to cause all display digit segments,
play Test
decimal points, LED's, and light bars to be lighted. Release button to re-
turn to normal mode.
T-5 Segments
Tests each individual display segment (all digits simultaneously) in order
Test
to assess whether any segments might be bridged together.
Press and release any number button to step through the test sequence
manually, or press and release the Timer button to run the test sequence
automatically one time through.
T-6 Digits Test
Tests each individual display digit (all segments on, one digit at a time) in
order to assess whether any solder bridges between digits exist.
T T a a b b l l e e 6 6 - - 1 1 P P r r o o g g r r a a m m m m i i n n g g
Description
165

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

561

Table of Contents