Henny Penny 500 Service Manual page 245

4-head electric pressure fryers
Hide thumbs Also See for 500:
Table of Contents

Advertisement

8 8 . . 1 1 7 7 . . 3 3 P P l l u u m m b b i i n n g g L L e e a a k k s s D D u u r r i i n n g g C C o o o o k k i i n n g g
Before test, disconnect the dairy unit where the drain pan connects to the oil
1 1 ) )
return line.
While the fryer is pressurized to 12 psi, inspect both the drain valve and the
2 2 ) )
dairy union connection for leakage:
• If there is significant leaking, more that just a drop every now and then detected
from the drain valve, then replace it.
• If there is significant leaking, more that just a drop every now and then detected
from the oil return line, then replace it.
8 8 . . 1 1 8 8 M M e e a a s s u u r r e e A A M M P P D D r r a a w w
T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l s s h h o o c c k k o o r r p p r r o o p p e e r r t t y y d d a a m m a a g g e e , , m m o o v v e e t t h h e e
p p o o w w e e r r s s w w i i t t c c h h t t o o o o f f f f a a n n d d d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r
u u n n p p l l u u g g c c o o r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .
Ensure that the amp draw of the fryer equals the amp draw listed on the data label.
This is important because if amp draw is less than what is listed on the fryer's data
label, this is an indication that one of the phases that comes into the fryer may be
missing. Additionally, there may be an issue with one of the contactors or there may
be an issue in one of the heating elements.
231