Introduction; Control Panel Wire Removal - Henny Penny FM07-020-F Operator's Manual

Kentucky fried chicken computerized control
Table of Contents

Advertisement

1-3. INTRODUCTION

1-4. CONTROL PANEL WIRE
REMOVAL
1-2
Installation of the KFC Computerized Control Panel on existing
Henny Penny gas pressure fryers.
Disconnect the fryer from the electrical supply source
before beginning panel conversion.
Failure to disconnect the fryer from the supply source
could result in electrical shock.
The fryer internal wiring is numbered to correspond to the
numbers on the wiring diagram, Figure 1.
A. Remove the four screws holding the existing control panel in
place.
B. Position the control panel for servicing by placing the lower
edge of the control panel on top of fryer frame and door.
C. Identify the locations of the following wires. Reference wire
diagram Figure 1.
Wire
Wire Number
Neutral
Motor
34
Motor
33
L 1
Fan
10
Solenoid
31
Solenoid
32
Hi Limit & Fan
Gas Valve
12
Pin Number
9 Pin Conenctor
2
1
9
7
1
3
4
6
8
8
2
5
Location
Main Power Switch
Main Power Switch
Main Power Switch
Main Power Switch
Main Power Switch
Main Timer
Soft/Crisp Switch
Wiring Harness
Gas Valve
304