2 2 . . 1 1 9 9 W W i i r r i i n n g g D D i i a a g g r r a a m m s s
Illustrations of the wiring diagram for Henny Penny Models 500, 561, and 600
Pressure Fryers are found in
If there is any doubt about which wiring diagram to use, please contact your
distributor. As with all contacts to the distributor, include the model number and serial
number form the data plate on your unit.
Refer to to explain the wire naming system for April 1, 2006
NOTICE:
and after.
2 2 . . 2 2 0 0 C C a a s s t t e e r r R R e e p p l l a a c c e e m m e e n n t t P P r r o o c c e e d d u u r r e e
Casters on the fryer cannot be adjusted. Replace any damaged or broken casters by
doing the following:
Discard oil from the fryer.
1 1 ) )
Using two floor jacks, position jacks near casters under the frame at point A.
2 2 ) )
Both jacks must be positioned near casters on the same side of the fryer. For
example, lift both the front casters off of the ground if replacing a front caster.
Block the casters on the opposite side of the fryer with small wheel chocks.
3 3 ) )
Raise fryer approximately 2.5" (63mm).
4 4 ) )
Use an adjustable wrench at point B. to remove the existing caster.
5 5 ) )
Install the new caster in reverse order.
6 6 ) )
2 2 . . 2 2 1 1 S S o o l l e e n n o o i i d d V V a a l l v v e e
N N O O T T E E :
This is an electromechanical device that causes pressure to be held in the vat (frypot).
The solenoid valve closes at the beginning of the cook cycle and is opened
automatically by the timer at the end of the cook cycle. If the valve should become
dirty or the te-Aon seat nicked, pressure will not build up. The solenoid valve used on
all models is the same with the exception of the coil. The gas model fryer uses a 120
volt, 60 Hz, coil. The electric model fryer uses a 208/240 volt 60 Hz coil. The 440/480
volt electric model uses a transformer to drop voltage to 220/240 volts.
Chapter 7 Wiring Diagrams , page
T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l s s h h o o c c k k o o r r p p r r o o p p e e r r t t y y
d d a a m m a a g g e e , , m m o o v v e e t t h h e e p p o o w w e e r r s s w w i i t t c c h h t t o o
O O F F F F
a a n n d d
b b r r e e a a k k e e r r , ,
r r e e c c e e p p t t a a c c l l e e . .
Most Controls use 24 volt solenoids. The
C1000 & C2000 Controls use line voltage