8 8 . . 9 9 I I n n s s p p e e c c t t t t h h e e C C o o n n d d e e n n s s a a t t i i o o n n B B o o x x
Clean the condensation box and drain lines, removing all debris. Use a flexible wire
brush to remove debris from the condensation drain line.
Remove the fryer's rear cover.
1 1 ) )
Disconnect the deadweight tube (A).
2 2 ) )
Disconnect the condensation drain line (C).
3 3 ) )
Disconnect the plumbing from the pressure solenoid (B).
4 4 ) )
Remove the condensation box mounting screws.
5 5 ) )
Cut the silicone, which seals the rear cover.
6 6 ) )
Remove the six screws fastening the interior of the box to the exterior (D).
7 7 ) )
Remove any debris from the inside of the condensation box and clean.
8 8 ) )
Remove any debris in the condensation drain line (not shown) and in the
9 9 ) )
condensation drain outlet.
Slide assembly back together and seal with silicone.
1 1 0 0 ) )
Reassemble in reverse order.
1 1 1 1 ) )
8 8 . . 1 1 0 0 I I n n s s p p e e c c t t t t h h e e S S o o l l e e n n o o i i d d a a n n d d D D e e a a d d w w e e i i g g h h t t P P l l u u m m b b i i n n g g
Inspect that the plumbing from the dead weight valve and the pressure solenoid are
clean, and free from debris.
• During the lid locking safety inspection if pressure exceeded 14 psi, this would
indicate blockage in either the dead weight assembly or in the dead weight
plumbing.