Problem
Pressure will not ex-
haust at end of cook
cycle.
Operating pressure
too high.
Pressure does not
build.
6
Cause
P P r r e e s s s s u u r r e e S S e e c c t t i i o o n n
Exhaust line from solenoid
valve to expansion tank
clogged.
Solenoid valve clogged.
Deadweight clogged.
Exhaust line to stack
clogged.
Not enough product in fryer
or product not moist.
Metal shipping spacer not re-
moved from deadweight.
Lid open or not latched.
Solenoid valve leaking or not
closing.
Deadweight valve leaking.
Main timer not closing
solenoid.
Lid gasket leaking.
Correction
Check cord and plug per
Electrical Components , page
Check circuit breaker on single
phase fryers.
Release pressure from vat (frypot);
clean all pressure lines, exhaust
stacks.
Check and clean solenoid valve per
2.16 Pressure Regulation/Exhaust ,
page
44.
Place proper quantity of moist prod-
uct within vat (frypot) to generate
steam.
Clean exhaust line to stack.
Place proper quantity of moist prod-
uct within vat (frypot) to generate
steam.
Remove shipping spacer per Opera-
tor's Manual.
Close and latch lid.
Check and clean solenoid valve per
2.16 Pressure Regulation/Exhaust ,
page
44.
Repair per
2.16 Pressure Regula-
tion/Exhaust , page
44.
Check main timer per
2.15 Timing
Control , page
41.
Adjust lid limit stop; if this does not
correct the problem, reverse the lid
gasket; if this fails to correct the
problem, replace the lid gasket.