SSA RAID Adapter, SSA, and RAID
6
Observe the Status column on
the screen. If the status of any
disk drive is 'Failed', that disk
drive is failing. In the example
shown here, the fourth disk drive
is failing.
ISSACFG SSA Configurator and Service Aids
VYYlI1TIdd
OS2 Version
Main Menu
I
I
Disk Service Aids
Is one of the disk drives failing?
YES
NO
~
Go to step 8.
-
link
Port Al
Port A2
Port BI
Port B2
SSA UID
Status
UIDxxxxx
UIDyxxxx
UID3xxxx
UID4xxxx
Failing
No di sks
<ESCAPE> Exit <ENTER> Select <Fl> Help <F2> Fonnat
<F3> Certify <F4> ServiceMode <FS> Diagnostics <F9> FlashOn
<flO> Fl ashOff
7
• Use the Identify function (as instructed on the
screen) to find the failing disk drive. See
"Finding the Physical Location of a Device" on
page 125 if you need more information about
finding the disk drive.
• Exchange the disk drive for a new one (see
"Disk Drive Assembly (HDA) Removal and
Replacement" on page 164).
Go to "SSA - Repair Verification" on page 1 09 to
verify the repair.
Chapter 7. The SSA RAID Adapter, SSA, and RAID