13.2 Voltage measurement on a U-interface

Measurement of feed voltage on a U-interface
Measurement of the U-interface under load
The ARGUS measures the voltage on the U-interface under
various selectable loads and also displays the calculated
current and power.
From these values, it is possible to estimate the length of the
line.
ARGUS 3u plus/3u NT
13 Level Measuring
Use the <
> to select
Voltage U.
Start measurement
The ARGUS will display the
level of the feed in volts.
The measurement will be
updated continuously.
Use the <
> to select Power
U.
Start measurement
The ARGUS displays the
switched-in load in kΩ, the
measured voltage in Volts
(should not
>100V),
calculated power in mW and
the calculated current in mA.
Use <++> to increase the
load by one increment (the
resistance is lowered)
Use <--> to decrease the
load by one increment (the
resistance is increased)