Bri Passive Trace/Monitor (Optional) - Intec Argus 3u plus Manual

Table of Contents

Advertisement

8.1.3 BRI Passive Trace/Monitor (optional)

In the Pass.trace mode, the ARGUS passively monitors the
connected BRI access (signals from the remote end and the
signals it sent to the NT itself) .
The ARGUS sends the captured D-channel signals via the
serial interface to the connected PC, which must be running
either ARGUS WINplus or ARGUS WINAnalyse. Neither the
S-Bus nor Layer 1 are influenced.
In Monitor mode, the ARGUS also monitors signals sent
from other TEs to the NT.
ARGUS 3u plus/3u NT
8 Select the Access Mode
With the <
>, select BRI
pass. trace.
Confirm the selected access
mode
The ARGUS evaluates the
level on the NT-side: OK, <<
(too low), >> (too high), _ (no
level)
(Pass. trace not yet active)
Start recording
The Trace LED lights.
The ARGUS displays the
number of recorded signals
(e.g. 25) and the recording
time in h:min:sec.
Select < ABORT> : Stop
recording.
Select < LISTEN > : and the
B-channel select dialog will
open.
After selecting a B-
channel, it will be possible to
listen to the voice data on this
channel
(in
the
Network -----> User).
direction
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Argus 3u nt

Table of Contents