Test steps on the ARGUS:
Sample test results – Line Test:
wires: Term. wrong", the measurement conditions
with respect to the location or complexity of the fault
are unfavorable.
In this case, you should change the measurement
conditions in the following manner:
Remove the terminating resistors from the bus and
repeat the test.
Frequently it is enough to simply swap the test
adapter and the ARGUS.
Comments about the test results:
-
The bus can first be considered to be free of defects,
when all of the sockets have been tested as OK.
-
Short-circuits are reported as a resistance value < 10 Ω Ω Ω Ω .
-
Crossed wires and broken connections between the test
adapter and the terminating resistor cannot be found.
ARGUS 3u plus/3u NT
7 Setting the type of access
With the <
>, select
Line Test.
Start the Line Test
No errors occurred.
Wires 3 and 6 are crossed.
If the message "Crossed
29