9 Single Tests

9.3.1 Start BERT

The following parameters are required for the BERT:
-
Duration of the BERT (default setting = 1 minute)
-
Error level: If the bit error rate exceeds this limit, the
ARGUS will display the test result NO. If the bit error
rate is less than this limit, the ARGUS will display an OK
(default setting = 10
-
HRX value in % (hypothetical reference connection see
ITU-T G.821) (default setting = 15%)
-
Bit pattern, which will be sent during the test
(default setting = 2
The parameters can be changed individually and saved (see
"Configuration: BERT" on page 119.).
60
-05
)
15
-1)
In the Single tests menu,
use the <
error test.
Use <
> to select BERT
start.
Enter your
Own number to perform the
BERT in an extended call to
oneself (two B-channels).
ora
remote number for a BERT
to a loopbox (one B-channel)
or end-to-end
Confirm the number
Using the <
service which should be
used for the BERT.
Confirm the service.
Enter the B-channel on the
keypad. If you enter an *, the
ARGUS will choose any B-
channel that is free.
BERT start
ARGUS 3u plus/3u NT
> to select Bit
> , select the