6 Automatic Access Test

Using the included cable, connect the ARGUS to the access
to be tested.
Power Key: Switch on the ARGUS.
If the test fails or if you wish to provoke a specific error
situation, you can manually select any interface in the
Access menu later (see "Setting the type of access" on page
26).
Initializing the ARGUS :
- Operating the ARGUS on a BRI or U-Interface access:
The ARGUS will first setup Layer 1. While Layer 1 is being
setup, LED L1 over the display will blink. If the ARGUS
cannot setup Layer 1, it will display the message "No Net".
When the ARGUS is operated on a U-interface access, it
can take up to 2.5 minutes to activate Layer 1.
As soon as Layer 1 is successfully setup, LED L1 will light
continuously.
Once Layer 2 has been setup LED L2 will light.
ARGUS 3u plus/3u NT
6 Automatic Access Test
The ARGUS automatically
performs an access test
(Automatic setting in the
Access menu see Page 26).
No
manual
entries
required. The
The access under test (BRI,
U interface or POTS) can
also
be
connected
afterwards.
If the ARGUS finds a DC
voltage on the 2-wire line (U-
Interface or POTs), it will
check whether there is a HF
signal on the line.
With < TE >: determine the
access
are
21