9.9.3 Time measurement: Interchannel delay

The ARGUS establishes two separate connections to a
remote loopbox. The loopbox sends the respective B-
channel data back on the same channel. The ARGUS
measures the propagation delay for the data on each of the
B-channels and determines the difference between the two
propagation delays (interchannel delay).
The ARGUS disconnects automatically as soon as the
measurement is completed.
ARGUS 3u plus/3u NT
9 Single Tests
In the Single tests menu, use
the <
> to select Time
measuring.
Use the <
> to select
Interchan.delay.
Enter - or select from the
speed-dialing memory - the
call number of the loopbox
Use the <
> to select the
service.
Perform measurement
The ARGUS displays the
propagation
delay
milliseconds
and
(multiples of the time required
to send a bit at 64 kBit/s, it
takes 15.26 µsec to send a
bit).
The measurement will be
repeated in cycles.
Press <ABORT> to stop the
measurement.