D) ARGUS Error Messages

Fault
Fault
Cause
Number
Class
.
E
Network
0
B,C,D,E Network
1 to 127
E
ARGUS
150
B
ARGUS
152
E
ARGUS
153
E
ARGUS
154
B
ARGUS
161
B
ARGUS
162
E
ARGUS
163
ARGUS
170
B
ARGUS
199
ARGUS
200
A
ARGUS
201
144
Description
The network is not in a state
defined for DSS1 or 1TR6. It
may be that this state is normal
for a PBX.
DSS1 or 1TR6 causes
An error occurred during the
supplementary service test.
Frequent cause: no response
from network
The CF-Test was started with
the wrong own number.
.
no HOLD is available, but HOLD
is required to test the
supplementary service (ECT,
3pty)
CLIR or COLR could not be
tested, since CLIP or COLP is
not available
The party called did not answer
within the prescribed time
(approx.10 sec)
A call was setup to a remote
subscriber, instead of being
setup – as was expected – to
your own number.
The Auto-Test could not setup a
connection and therefore the
AOC/D supplementary service
could not be tested.
During the Suppl.services test, a
call came in without a B-channel
(call waiting). Therefore, it was
not possible to accept the call
and test.
A call number was entered.
Internal error
Network did not confirm
acceptance of the call (CONN
sent, no CONN_ACK received
from network)