Intec Argus 3u plus Manual page 21

Table of Contents

Advertisement

confirmation key and the < ↓ ↓ ↓ ↓ > softkey performs the same
function as the corresponding arrow key on the ARGUS
keypad.
In the example above, the test found that it is a BRI multiple
device access using the DSS1 protocol
Shown on the second line in the display:
The availability of the B-channels:
B12
both channels are available
B1-
only B-channel 1 is available
B-2-
only B-channel 2 is available
B--
no B-channel available
If only one B-channel is available, this can have an
impact on the service check and the testing of the
supplementary services.
Level evaluation only on a BRI access:
OK
the level is in order
<<
the level is too low
>>
the level is too high
--
no level
Shown on the third line in the display:
Access Mode:
TEs = TE Simulation Slave Mode
TEm = TE Simulation Master Mode
Bus configuration:
P-P:
Point-to-Point
P-MP: Point-to-Multipoint
It must be mentioned again, that the ARGUS only
determines the general bus status once when switched on
or when the ARGUS first connected.
On the other hand, the status of the protocol stacks for Layer
1, 2 and 3 will be continually monitored and displayed.
ARGUS 3u plus/3u NT
6 Automatic Access Test
23