Intec Argus 3u plus Manual page 67

Table of Contents

Advertisement

the results.
Test results:
TEI 02 = the first valid TEI value is 02.
+ +
= Both test steps were successful
+ -
= the first test step was successful, the second step
not In this case, the ARGUS will display the relevant
X.31 cause for the failure (in the example above: 13)
and an associated diagnostic code (in the example:
67), if there is one
messages" on page 145.).
If the X.31 service is not supported, the ARGUS will report
"X.31 (D) n. impl.".
ARGUS 3u plus/3u NT
9 Single Tests
In the Single tests menu,
use
> to select the X.31 test.
<
Use <
> to select
Automatically.
Start test
The test can take up to 4
minutes (a rotating bar will
be displayed). Beginning on
the left, the ARGUS will
display the TEI currently
being tested followed by the
one previously tested and its
result:
+ = X.31 is available for this
TEI
- = X.31 is not available for
this TEI
Once the test has ended, the
ARGUS will show whether
the X.31 service is available
for Layer 3 for the TEIs
found in Step 1.
Using the <
>, scroll through
(see "X.31 Test – Error
69