Parameters
0-12 Link Setups
Option:
Function:
[20] Linked
Copies "not changeable during operation"
parameters from one set-up to the other, so they
are identical in both set-ups.

3.1.3 0-3* LCP Custom Readout

It is possible to customize the display elements for various
purposes: *Custom Readout. Value proportional to speed
(linear, squared or cubed depending on unit selected in
0-30 Custom Readout Unit) *Display Text. Text string stored
in a parameter.
Custom Readout
The calculated value to be displayed is based on settings
in 0-30 Custom Readout Unit, 0-31 Custom Readout Min
Value (linear only), 0-32 Custom Readout Max Value,
4-14 Motor Speed High Limit [Hz] and actual speed.
Custom Readout (Value)
P 16-09
Custom Readout
Unit P 0-30
Max value
P 0-32
Min value
Liniar
units only
P 0-31
0
Figure 3.1
The relation will depend on the type of unit selected in
0-30 Custom Readout Unit:
®
VLT
HVAC Basic Drive Programming Guide
Unit Type
Dimensionless
Speed
Flow, volume
Flow, mass
Velocity
Length
Temperature
Pressure
Power
Table 3.1
0-30 Custom Readout Unit
Option:
[0]
[1]
[5]
[10]
[11]
[12]
[20]
[21]
[22]
[23]
Motor Speed
[24]
[25]
Motor Speed
[30]
High limit
P 4-14 (Hz)
[31]
[32]
[33]
[34]
[40]
[41]
[45]
[60]
[70]
[71]
[72]
[73]
[74]
[80]
[120] GPM
[121] gal/s
[122] gal/min
[123] gal/h
®
MG18B222 - VLT
is a registered Danfoss trademark
Speed Relation
Linear
Quadratic
Cubic
Function:
Program a value to be shown in the
display of the LCP. The value has a linear,
squared or cubed relation to speed. This
relation depends on the unit selected (see
table above). The actual calculated value
can be read in 16-09 Custom Readout.
None
%
PPM
l/Min
RPM
Pulse/s
l/s
l/min
l/h
m3/s
m3/min
m3/h
kg/s
kg/min
kg/h
t/min
t/h
m/s
m/min
m
Degree Celsius
mbar
bar
Pa
kPa
m Wg
kW
3
3
3-3