Danfoss VLT HVAC Basic Drive FC 100 Series Programming Manual page 35

Hide thumbs Also See for VLT HVAC Basic Drive FC 100 Series:
Table of Contents

Advertisement

Parameters
1-10 Motor Construction
1-20 Motor Power [kW]
1-22 Motor Voltage
1-23 Motor Frequency
1-24 Motor Current
1-25 Motor Nominal Speed
1-26 Motor Cont. Rated Torque
1-29 Automatic Motor Adaption
(AMA)
1-30 Stator Resistance (Rs)
1-33 Stator Leakage Reactance
(X1)
1-35 Main Reactance (Xh)
1-37 d-axis Inductance (Ld)
1-39 Motor Poles
1-40 Back EMF at 1000 RPM
1-52 Min Speed Normal
Magnetizing [Hz]
1-60 Low Speed Load Compen-
sation
1-61 High Speed Load Compen-
sation
1-62 Slip Compensation
1-63 Slip Compensation Time
Constant
1-64 Resonance Dampening
1-65 Resonance Dampening Time
Constant
1-66 Min. Current at Low Speed
1-71 Start Delay
1-72 Start Function
1-73 Flying Start
1-80 Function at Stop
1-82 Min Speed for Function at
Stop [Hz]
1-90 Motor Thermal Protection
1-93 Thermistor Source
2-00 DC Hold Current
2-01 DC Brake Current
2-02 DC Braking Time
2-04 DC Brake Cut-in Speed [Hz]
2-06 DC Brake Current
2-07 DC Braking Time
2-10 Brake Function
2-16 AC brake Max. Current
2-17 Over-voltage Control
4-10 Motor Speed Direction
4-12 Motor Speed Low Limit [Hz]
4-14 Motor Speed High Limit [Hz]
4-18 Current Limit
®
VLT
HVAC Basic Drive Programming Guide
[0] Asynchron
[1] PM
Motor non-
salient
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
®
MG18B222 - VLT
is a registered Danfoss trademark
1-10 Motor Construction
4-19 Max Output Frequency
4-58 Missing Motor Phase
Function
14-40 VT Level
14-41 AEO Minimum Magneti-
zation
Table 3.2
3.2.3 1-10 Motor Construction
1-10 Motor Construction
Select the motor construction type.
Option:
Function:
[0] Asynchron
For asynchronous motors.
[1] PM, non salient
For permanent magnet (PM) motors.
SPM
Note that PM motors are divided into
two groups, with either surface mounted
(non-salient) or interior (salient) magnets.
NOTE!
Only available up to 30 hp [22 kW]
motor power.
NOTE!
Motor construction can either be asynchronous or
permanent magnet (PM) motor.
3.2.4 1-14 - 1-17 VVC
plus
The default control parameters for VVC
core are optimized for HVAC applications and inertia load
in range of 50>Jl/Jm>5, were Jl is load inertia from the
application and Jm is machine inertia.
For low inertia applications Jl/Jm,<5 it is recommended
that 1-17 Voltage filter time const. be increased with a
factor of 5‒10 and in some cases 1-14 Damping Gain
should also be reduced to improve performance and
stability.
For High inertia applications Jl/Jm>>50, it is recommended
that 1-15 Low Speed Filter Time Const., 1-16 High Speed Filter
Time Const. and1-14 Damping Gain be increased to improve
performance and stability.
For high load at low speed [<30% of rated speed] it is
recommended that 1-17 Voltage filter time const. is
increased due to non-linearity in the inverter at low speed.
1-14 Damping Gain
Range:
120 %
[ 0 - 250 %]
*
[0] Asynchron
[1] PM
Motor non-
salient
x
x
x
x
x
PM
plus
PMSM control
Function:
3-7
3
3