Commissioning | Steps for commissioning
Further information:
HEIDENHAIN | GAGE-CHEK 2000 | Operating Instructions | 12/2018
If the linear encoder has coded reference marks, enter
the Maximum traverse path (see " Linear encoders",
Page 88)
If the angle encoder has coded reference marks, enter the
parameter for the Nominal increment (see "Angle encoders",
Page 90)
Confirm the entry with RET
Use the ON/OFF sliding switch to activate or deactivate
Inversion of reference mark pulses
Tap Reference point displacement
Use the ON/OFF slide switch to activate or deactivate
Reference point displacement (calculation of the offset
between the reference mark and the machine zero point)
If activated, enter the offset value for Reference point
displacement
Confirm the entry with RET
As an alternative, you can tap Apply in Current position for
reference point shift in order to apply the current position
as the offset value
In order to switch to the previous display, tap Back twice
Use the ON/OFF sliding switch to activate or deactivate the
Terminating resistor
Select the type of error monitoring in the Error monitor
drop-down list:
Off: Error monitoring not active
Frequency: Error monitoring of signal frequency
Select the desired counting direction in the Counting
direction drop-down list:
Positive: The direction of traverse is in the counting
direction of the encoder
Negative: The direction of traverse is opposite to the
counting direction of the encoder
"Axes X, Y ...", Page 177