HEIDENHAIN GAGE-CHEK 2000 Operating Instructions Manual page 82

Evaluation unit
Hide thumbs Also See for GAGE-CHEK 2000:
Table of Contents

Advertisement

7
Further information:
82
Tap Axes
Tap X or, if applicable, Not defined
If applicable, select the name of the axis in the Axis name
drop-down list
Tap Encoder
Specify the connection for the corresponding encoder in the
Encoder input drop-down list:
X1
X2
X3
The available encoder information is transmitted to the
product
The settings are updated
For encoders with an EnDat 2.2 interface: If the
corresponding encoder input has already been
assigned to an axis in the device settings, then the
encoder is automatically detected upon restart, and
the settings are adapted. Alternatively, you can assign
the encoder input after you have connected the
encoder.
Select the type of encoder in the Encoder model drop-down
list:
Linear encoder
Angle encoder
Angle encoder as linear encoder
If Angle encoder as linear encoder is selected, enter the
Mechanical ratio
Tap Reference point displacement
Use the ON/OFF slide switch to activate or deactivate
Reference point displacement (calculation of the offset
between the reference mark and the machine zero point)
If activated, enter the offset value for Reference point
displacement
Confirm the entry with RET
As an alternative, you can tap Apply in Current position for
reference point shift in order to apply the current position
as the offset value
To switch to the previous display, tap Back
To view the electronic ID label of the encoder, tap
Identification label
In order to see the results of the encoder diagnosis, tap
Diagnosis
"Axes X, Y ...", Page 177
Commissioning | Steps for commissioning
HEIDENHAIN | GAGE-CHEK 2000 | Operating Instructions | 12/2018