Connection Example - Honeywell EK280 Applications Manual

Volume converter
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280
Important parameters:
Parameter
Mode output 2
Value to be output
Lower adjustment value
Upper adjustment value
Lower output frequency
Upper output frequency
Output access

6.6.4 Connection example

Example
EK280 in Ex-Zone1; Ex isolation of outputs through the FE260; Use of a frequency/current converter type
"TURCK – IM21-14EX-CDTRI" (Honeywell Order No.: 04 015 163)
Always comply with the information in the Operating Instructions for the equipment listed and with the
relevant safety regulations.
Application Manual
Abbreviation LIS address
Md.O2
02:605
Sc.O2
02:606
Aj1.O2
02:622
Aj2.O2
02:623
f1.O2
02:624
f2.O2
02:625
Seal.
02:60E
Value
Notes / meaning
(examples)
8
HF-pulses
02:310_0
Qb
04:310_0
Qm
0
"0" m3/h
1800
"1800" m3/h
0
"0" Hz
500
"500" Hz
No
Without access restriction
53