Installation, connection and commissioning

6
6.1

Installation

The EK205-M can be installed either on the gas meter, on the pipeline or on a wall.
In the event of issues during installation, e.g. when selecting the suitable installation
accessories, please contact our customer service (see section General).

6.1.1 Installation on a gas meter

Install the EK205-M on a gas meter using a mounting bracket (see Appendix) as well
as suitable cylinder screws and square nuts.
1
5
Fig. 5

6.1.2 Installation on a pipeline

Using pipe installation aids (see Appendix) with suitable cable ties, install the EK205-
M on a pipeline.
3
Fig. 6
4
2
1
4
Installation, connection and commissioning
1. Using two self-cutting screws (6),
install the mounting bracket (3) on the
EK205-M (1)
2. Tighten the self-cutting screws such
that the angle is tight.
3. Using two M5 square nuts (4) and two
M5 x 10 mm cylinder screws (2 ),
6
install the mounting bracket on the rear
of the meter head (5).
3
4. Tighten the cylinder screws such that
the device sits tight and cannot fall
2
down.
1. Using the four self-cutting screws provided
(1), install the pipeline installation aid (2) on
the rear of the EK205-M (3).
2. Tighten the cylinder screws such that the
installation aid sits tight.
3. Fasten the EK205-M with installed pipeline
installation aid (2 and 3 ) with the help of
cable ties on the pipeline ( 4 ).
4. Install the device such that it sits tight and
cannot fall down.