More information on the configuration of the DM130 can be obtained from its' documentation.
7.5.5.4 Retrieving data with enSuite
a) Opening the test time window for the following test retrievals with enSuite
i
The test time window only needs to be open if none of the time windows 1 to 6 are open.
If no communication link to the EK280 via the optical interface exists, it must be created
( chapter 3.1).
Select "Navigation" on the left-hand side of the enSuite window and then
the bottom of the navigation window.
At the top of the device window open the path "Parameter" > "Interfaces" by clicking on the relevant
plus sign, and then select "internal modem" (not the plus sign before that).
Click on the "0" value next to
and enter a period in minutes (e.g., 10), for the test time window retrieval to remain open. For a
battery-operated EK280 please do not enter an excessively long duration, as this will adversely
affect the battery life.
Press
"Transfer changes to
The EK280 is now available via the modem for the duration set.
In enSuite press the "Disconnect" or
interface communication link between enSuite and the EK280.
b) Test retrieval via the modem
Set up the modem communication link between enSuite and EK280 ( chapter 3.2).
Once the communication link is set up, you can carry out checks, for instance view certain
parameters. To do this press "Navigation" on the left-hand side of the enSuite window and then
"Parameterize
online" at the bottom of the navigation window, then click on the plus sign next to
"Parameter" and then its subsections.
In enSuite press the

7.6 Data transfer verification

Before the actual data transmission, the communication link (e.g., call window, modem used) for a
destination must be specified. Eight separate connections can be programmed.
i
For parameterization of the EK280 you need a connection cable for the optical interface as well
as the enSuite program version 2.4 or higher. enSuite can be downloaded free of charge from
the Honeywell website in the "Software Downloads" section:
www.elster-instromet.com/en/software-downloads
Application Manual
"Test call acceptance
device" icon at the top edge of the enSuite window.
"Disconnect from all
"Disconnect"
symbol or
"Disconnect from all devices"
"Parameterize
window" on the right-hand side of the window
devices" icon to terminate the optical
to end the test retrieval.
161
online" at