Honeywell EK280 Applications Manual page 150

Volume converter
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280
k) b)
Send parameter file
l)
Send the following parameter file to the EK280 ( chapter
EK280_xvx. - RS232 (without Modem) (*)
For the following customized settings and tests required, press "Navigation" on the left-hand side
and then
"Parameterize
i
All the values listed in enSuite under "Parameters" can be found on the "Serv." display tab of the
EK280 under the same path.
m) c)
Setting time window for potential data retrievals
In the base configuration now displayed you can define time windows, during which data can be cyclically
retrieved from the EK280 via the modem. Time windows 5 and 6 are reserved for EK280 operation with a
direct RS232 connection, and generally only time window 5 is used. Redundant time windows can be
deactivated by setting the time window start and end to the same value.
In the top of the device window open the path "Parameters" > "Interfaces" by clicking on the relevant
plus signs, and then select
For call window 5, set the start to "00:00" and the end to "23:59" and then select the "Transfer
changes to device" icon at the top of the enSuite window.
Press the
"Transfer changes to
7.5.1.4 Retrieving data with enSuite
Start the enSuite program (i.e.
terminals.
Select the
"Search device..."
In the "Search device and connect" window select the
Select
"Access"
default
settings".
Press "OK".
After a few seconds "connected" is displayed at the bottom of the "Output" window.
Once the communication link is set up, you can carry out checks, for instance view certain
parameters. To do this press "Navigation" on the left-hand side of the enSuite window and then
"Parameterize
online" in the bottom of the navigation window, then click on the plus sign next to
"Parameters" and then its subsections.
In enSuite press the "Disconnect" symbol or
35
The "x" stands for the version of software on the device, e.g. "2v2".
The star * stands for a small letter which indicates the version of the file, e.g. "a".
Application Manual
online" at the bottom of the navigation window.
"Call time
windows".
device" icon at the top of the enSuite window.
Start > Programs > Elster >
icon (magnifying glass icon).
"LIS200", "User"
 "Administrator", "Connection" 
3.6 Send parameter
35
enSuite) on the PC connected to the
"LIS200"
tab.
"Disconnect from all
devices" to end the test retrieval.
file, p. 21):
"Serial
RS232" and
"use
148