When parameterizing on location:
Make sure that time windows 5 and 6 of the EK280 are closed.
Make sure that the FE260 is not under power.
On the modem adapter board, fit the jumper "Mode" in position "program" (lower position,  photos).
Connect a COM interface of your computer with the modem parameterization interface on the
modem adapter board ( photograph) with the aid of a DSUB9-RS232 cable.
Turn on the FE260 power supply.
The following steps are performed either when parameterizing on site or remotely via a GSM-CSD modem
connection:
On your computer, start the software enSuite (version V3.9 or higher).
In enSuite, depending on the connection, open menu
Select the "ComTCPserv" tab.
Enter the password for the remote parameterization in the "Access" section (factory setting = "0000")
In the "Connection" section, specify whether you want to parameterize the modem locally via a serial
RS232 interface with 19200 Baud or via a modem connection. In the latter case, you must also enter
the telephone number under which the modem to be parameterized can be reached:
Application Manual
Jumper "Mode" in Position "program" (lower position)
Modem parameterization interface
CAUTION! 230 V alternating voltage! Risk to life!
"Actions"
>
"Search device
125
(F3)".