EK280
When parameterizing on location:
−
Make sure that time windows 5 and 6 of the EK280 are closed.
−
Make sure that the FE260 is not under power.
−
On the modem adapter board, fit the jumper "Mode" in position "program" (lower position, photos).
−
Connect a COM interface of your computer with the modem parameterization interface on the
modem adapter board ( photograph) with the aid of a DSUB9-RS232 cable.
−
Turn on the FE260 power supply.
The following steps are performed either when parameterizing on site or remotely via a GSM-CSD modem
connection:
−
On your computer, start the software enSuite (version V3.9 or higher).
−
In enSuite, depending on the connection, open menu
−
Select the "ComTCPserv" tab.
−
Enter the password for the remote parameterization in the "Access" section (factory setting = "0000")
−
In the "Connection" section, specify whether you want to parameterize the modem locally via a serial
RS232 interface with 19200 Baud or via a modem connection. In the latter case, you must also enter
the telephone number under which the modem to be parameterized can be reached:
Application Manual
Jumper "Mode" in Position "program" (lower position)
Modem parameterization interface
CAUTION! 230 V alternating voltage! Risk to life!
"Actions"
>
"Search device
125
(F3)".